Art.-No. 559112

fischer TermoZ CS II 8/235

Top Features
  • The fixing is pushed through the insulation into the drill hole and is screwed in.
  • For countersunk monting, the setting tool TermoZ CS is required.
  • Optionally, the setting tool TermoZ CS can also be used for flush installation by turning the stopping disc.
  • When using the setting tool, the installation is completed when the stopping disc is flush with the insulation panel.
  • For countersunk mounting the anchor plate needs to be covered with a round cap. For a surface-flush assembly, a closing plug is not necessary.

Your advantages / Product description

The strong screw fixing for all insulation materials and substrates.
Advantages
  • Due to the steel compound screw of the TermoZ CS II, all facade insulations including the fire bar can be fastened securely.
  • The screw fixing is also approved for fixing ETICS to ceiling undersides.
  • The setting tool is used to countersink the anchor optimally, resulting in an even plaster layer without anchor marks.
  • Due to the special expansion zone of the anchor sleeve, the TermoZ CS II, is the first insulation anchor with an approval for hammer-drilled holes in vertically perforated bricks.
  • The plate design and sleeve labeling allow correct and intuitive application.
  • The closed plate does not allow dirt to be ejected and thus ensures a clean setting result.
  • The special geometry of the underhead plate reduces the necessary insertion torque for convenient and fast installation.
TermoZ CS II est la fixation à vis solide pour l'isolation des murs extérieurs pour la fixation sûre de tout panneau isolant sur tous les matériaux de construction solides et perforés. Développé pour les besoins des installateurs, TermoZ CS II est facile à utiliser et garantit une installation rapide. La fixation isolante TermoZ CS II est approuvée pour toutes les classes de matériaux de construction courantes A,B,C,D,E. L’outil de réglage CS garantit un processus de réglage optimal sans marques d’ancrage.
Youtube VideoYoutube VideoYoutube Video

Application and approval

Applications
  • Attachment of ETICS insulating boards on concrete and masonry
  • Flush installation in all conventional insulation materials
  • Flush installation of insulation materials such as polystyrene rigid foam panels and dense mineral wool panels
  • Fixing of ETICS insulating boards for new buildings and energetic building renovations
Building materials
  • Building material classes A, B, C, D, E
  • Concrete
  • Concrete (weather shell)
  • Building brick
  • Solid sand-lime brick
  • Hollow blocks made from lightweight concrete
  • Vertically perforated brick
  • Perforated sand-lime brick
  • Lightweight aggregate concrete
  • Aerated concrete
You can find detailed information on building materials in the approval document.
Approval
  • ETA-14/0372
  • DoP No. 0298
  • DoP No. 0346
  • EPD-FIW-20210314-CBD1-EN

Assembly instruction

Functionality
  • The fixing is pushed through the insulation into the drill hole and is screwed in. For ceiling soffits, the installation is carried out through the base plaster including fabric and insulation.
  • For countersunk mounting, the setting tool TermoZ CS is required.
  • Optionally, the setting tool TermoZ CS can also be used for flush installation by turning the stopping disc.
  • When using the setting tool, the installation is completed when the stopping disc is flush with the insulation panel.
  • For countersunk mounting the anchor plate needs to be covered with a closing cap.
  • For a surface-flush setting, a closing plug is not necessary.
Flush to surface installation with setting tool CS
1 / 5
Countersunk installation with setting tool CS
1 / 6

Technical Data

ETA-approval
Drill diameter (
d0
)
8 mm
Effect. anchorage depth (
hef
)
25 mm
Max. usable length at surface-flush installation (
tfix
)
210 mm
Min. total drill whole depth incl. insulation at surface flush installation (
h
)
250 mm
Max. usable length at countersunk installation (
tfix
)
210 mm
Min. total drill whole depth incl. insulation at countersunk installation (
h
)
265 mm
Drive TX30
Amount 100 pcs.
GTIN (EAN-Code) 4048962417289

Documents for Downloading

  • ETAs and DoPs
  • Sustainability
  • Technical documents
  • Sales materials
European Technical Assessment for fischer TermoZ CS II 8 and fischer TermoZ CS II 8 DT 110 V
Created on 11/03/2023
Declaration of Performance for fischer TermoZ CS II 8 / TermoZ CS II 8 DT 110 V (Plastic anchors for use in concrete)
Created on 11/17/2023
Declaration of Performance for fischer TermoZ CS II 8 / TermoZ CS II 8 DT 110 V (Plastic fastener for fixing of external thermal insulation composite systems with rendering)
Created on 05/16/2022
cd-green-58bb58464c-ppkw9